Hydronic Heating & Boiler Supplies
N&N Supply Stocks heating supplies focused on hydronic heating, or those that help transfer heat with the use of water.
- Air Separator (EAS-1)
- Air Scoop (431-6, 432-6, 433-5, 434-5)
- Air Gap (909AGA, 909AGC, 909AGF)
- Air Vent (PV100. PV100S. PV125, PV125S, PV150)
- Aquastats
- Backflow Preventers
- Circulator Pumps
- Expansion Tanks
- Flow Switch (IFS01BF-1)
- Flow Valves
- Low Water Cut Off
- Mixing Valves
- Relief Valves
- Switching Relay
- Transformers
- Venting
- Z-Flex
- Field Controls Dampers
- Tjernlund
- Hart & Cooley
- Water Feeders
- Zone Valves
The Honeywell EA79 Industrial Air Vent purges air from high pressure mains and equipment in hot or cold closed water systems.
Features
• Built-in shutoff valve for servicing without system shutdown.
• Built-in vacuum breaker.
• Removable float/valve assembly for easy servicing.
• Safety drain connection and vent cap with leakage guard.
• Brass shell construction.
The Honeywell SuperVent, purges air through a no clog vent assembly, to control dirt and debris and minimize air vent fouling in Hydronic heating systems, while eliminating the need for bleeding.
Features
• No clog vent.
• Dirt and Debris resistant.
• 360 degree adjustable collar ring for installation flexibility.
• Stainless steel concentrator which eliminates gurgling noise.
• Bronze body for rigid construction.
• Threaded connections.
3/4 PV075S
1 PV100S
1-1/4 PV125S
The Honeywell SuperVent, purges air through a no clog vent assembly, to control dirt and debris and minimize air vent fouling in Hydronic heating systems, while eliminating the need for bleeding.
Features
• No clog vent.
• Dirt and Debris resistant.
• 360 degree adjustable collar ring for installation flexibility.
• Stainless steel concentrator which eliminates gurgling noise.
• Bronze body for rigid construction.
• Threaded connections.
1 PV100
1-1/4 PV125
1-1/2 PV150
Series LF70A, LFL70A Hot Water Extender Tempering Valves are used in residential water supply applications to mix cold and hot water to extend capacity of water heater storage tanks and hot water boiler tankless heaters.
Stocking 1/2 or 3/4
Specs
Reduced Pressure Zone Assemblies
Series 009 Reduced Pressure Zone Assemblies prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure.
3/4 LF009M3QT 0391003
1 LF009M2QT 0391004
1-1/4 LF009M2QT 0391005
1-1/2 LF009M2QT 0391006
2 LF009M2QT 0391007
Lead Free Double Check Valve Assemblies
Series LF007 Lead Free Double Check Valve Assemblies prevent the backflow of contaminated water into the potable water supply.
3/4 LF007M2QT 0063231
1 LF007M1QT 0063232
1-1/4 LF007M2QT 0063233
1-1/2 LF007M2QT 0063234
2 LF009M1QT 0063235
Series LF7R Lead Free Dual Check Valves prevent the reverse flow of polluted water from entering into the drinking water supply at the service entrance or at individual outlets
LF7RU2-2 1/2
LF7RU2-2 3/4
LF7RU2-2 1
Honeywell AM-1 series adjusts, maintains, and limits the hot water temperature settings to provide comfort and protect equipment at home. While increasing the amount of safe, usable hot water, it efficiently offers anti-scald, anti-chill protection.
AM100-1LF 1/2
AM100C-1LF 1/2
AM101-1LF 3/4
AM101C-1LF 3/4
AM102-1LF 1
AM102C-1LF 1
Series LFUSG-B Under Sink Guardian Thermostatic Mixing Valves are used in commercial and residential applications to mix hot and cold water in under-the-sink installations to minimize the risk of accidental scalding.
Stocking 3/8OD Part # 0204143
Series LFP3 Lead Free Multi-Orifice Flow Control Valves for Tankless Heaters are for use in commercial and residential hydronic heating systems to limit the flow of water to equipment in tankless heater installations.
Series N9, N9C Dual Check Vacuum Breakers prevent the reverse flow of polluted water from entering into the potable water supply. It consists of a brass body construction with an atmospheric vent, and NPT female inlet and outlet connections.
Stocking 1/4 & 3/8
Series 9D Dual Check Valves with Intermediate Atmospheric Vent prevent the reverse flow of hot or cold polluted water from entering into the potable water supply.
Stocking 1/2 & 3/4
Lead Free Series LF150A Water Hammer Arrestors are used in residential applications to control water pressure shock and prevent water hammer conditions.
The noise from banging pipes is caused by shocks of high speed water flowing in the piping system when a fixture is suddenly closed. Sudden stoppage of the water (a non-compressible liquid) flowing at a given pressure and velocity causes a surge or spike of water and is called water hammer.
Series B911, B911S Bronze Combination Fill Valve and Backflow Preventers are for use in commercial and residential hydronic heating systems to provide make-up water to the boiler, and prevent backflow when supply pressure falls below system pressure.
Series B1156F Bronze High Capacity Feed Water Pressure Regulators are for use in commercial and residential hydronic heating systems to fill the boiler and piping system with water, and to maintain water pressure in the system at all times.
Series 1450F Dual Controls (Regulator and Relief Valve) are for use in commercial and residential hydronic heating systems to fill the boiler and piping system with water, and to maintain water pressure in the system at all times.
Series 8 Hose Connection Vacuum Breakers permit the attachment of portable hoses to hose thread faucets and prevent the reverse flow of polluted water into the potable water supply due to backsiphonage.
Series 288A Hot or Cold Water Anti-Siphon Vacuum Breakers prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage.
Stocking: 3/8, 1/2, 3/4, 1. 1-1/2. 2
Series LFN36 Lead Free Water Service Vacuum Relief Valves are used in water heater/tank applications to automatically allow air to enter into the piping system to prevent vacuum conditions that could siphon the water from the system and damage water heater/tank equipment.
Boiler Header Module Pro Hydronic Packages containing HP-BHM Boiler Header Module, ETX-30 Expansion tank, and B911S-M3 Fill Valve Assembly.
Undersink Mixing ValveCan be used as 3-port & or 4-port.
Mixed Outlet
Temperature: 80-120 Degrees
Max Pressure: 150 Psi
Min Pressure: 30 Psi
Max Flow: 3 GPM
Min Flow: .05 GPM
Built-In Integral Check Valves (Hot & Cold)
Size: 3/8 OD Compression
Taco Air Scoop's enlarged design with internal baffles slows the water velocity in order to provide a noiseless, air-free hydronic heating, cooling or combination system, by efficiently separating out the air from the water in any of these systems.
431-6 1 imch
432-6 1-1/4 inch
433-5 1-1/2 inch
434-5 2 inch
Air Gaps for Reduced Pressure Zone Assemblies provide an unobstructed, physical separation between the discharge end of a potable water supply line and an open receiving vessel.
909AGA
909AGC
909AGF
Installed on water or stream radiators the Taco automatic coin vent is the ideal air purging device. The vent can also be manually shut-off by means of an internal ball check. The 417 coin vent is suitable for use in water and low pressure steam applications.
Taco Flo-Cheks are used in forced hot water heating systems to prevent gravity circulation during periods when the boiler is hot, but the space heating zone is not wanted. This makes it possible to use the heating boiler to maintain domestic hot water year-round. You can also use Flo-Cheks in systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat.
218-3 3/4
220-6 1
221-6 1-1/4
222-6 1-1/2
223-5 2
The Taco Industrial Flow Switch (IFS) starts or stops electronically operated equipment when a flow or no flow condition occurs. The IFS can be used in 1" to 8"liquid flow lines, carrying water or any nonhazardous fluid not harmful to brass, stainless steel or EPDM. It is used in a wide variety of applications including heating systems, domestic water boosters, process work, water systems, chillers and on low mass boilers.
LFA0243S-1 Water/Steam LWCO 24 Volt Auto
LFM0243S-1 Water/steam LWCO 24 Volt Maual Reset
LFM1203S-1 Water/Steam LWCO 120 Volt Maual Reset
LTA1203S-2 Water LWCO 120 Volt Manual Reset (Used on CG and Pennco)
SR501-1 1-Zone Circulator
SR502 2-Zone
SR503 3-Zone
SR504 4-Zone
SR506 6-Zone
Bidirectional flow (you can't install the valve backwards)
The actuator mounts on the valve in either direction
125 PSI shut-off pressure with industry leading Cv's
Quick release actuator mounting clip Manual override button
Positional indicator shows the ball valve's actual position
Up to 12 valves on (1) 40VA transformer
Bidirectional flow (you can't install the valve backwards)
The actuator mounts on the valve in either direction
125 PSI shut-off pressure with industry leading Cv's
Quick release actuator mounting clip Manual override button
Positional indicator shows the ball valve's actual position
Up to 12 valves on (1) 40VA transformer
The FVX Series combination temperature and pressure relief valves are designed to offer high capacity protection for domestic and commercial water heating devices. The FVX Series Valves are fully automatic with the valves resetting after either temperature or pressure relief.
Stocking:
3/4" FVMX-5C Male Inlet 23255 150 PSI
1" FVMX-5C Male Inlet 23276 150 PSI
The FW and FWC Valves are small, low-cost relief valves suitable for static over-pressure protection. Type FWC incorporates a calibrated adjusting screw for occasional changes in pressure setting without the use of a pressure gauge.
The FWL-2 is a pressure only relief valve designed specifically for the protection of hot water supply systems where over-pressure conditions are likely to occur as a result of thermal expansion.
The F-82 is a pressure-only ASME relief valve designed for use on hot water space heating boilers, water supply heaters and storage tanks.
The F-82 Safety Relief Valves are designed for use on hot water service only and are not to be used on steam.
Stocking:
F82 3/4 30LB
F82 3/4 35LB
F82 3/4 50LB
F82 3/4 75LB
F82 3/4 100LB
F82 3/4 125LB
F82 3/4 150LB
F82 1 30LB
F82 1 35LB
F82 1 50LB
F82 1 150LB
Series LF100XL Temperature and Pressure Relief Valves are used in water heater and hot water storage tank applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 105,000 BTU/hr.
Stocking:
LF100XL-8 3/4 T&P 150lb
LF100XL 3/4 T&P 100lb
LF100XL 3/4 T&P 150lb (Long Shank)
Series 2 Duo-Cloz Manual Washing Machine Shutoff Valves are used in washing machine applications to manually control water flow and pressure from the hot and cold water supply piping to the flexible hoses feeding a washing machine.
Pressure relief valves are for protection against excessive pressure. Recommended for all water system installations to protect against damage to piping and pressure tanks. They are set at 75 P.S.I. and are adjustable to 150 P.S.I
Stocking: 1/2 & 3/4 inch
Pressure Rating: Adjustable from 75 to 150 P.S.I
Brass Body
Iron Pipe Straight Thread
Pressure relief valves are for protection against excessive pressure
Spring is made of Stainless Steel
As system fluid enters through the inlet, (either straight or angle) the diffuser distributes flow evenly across the stainless steel, wire brush-like medium. Air bubbles, even micro air bubbles, stick to the brush filaments. Trapped air rises above the diffuser through a baffle where the air is then released through an opening at the top. Treated water then goes back into the system.